Voltage Input | - Single Phase AC 208 - 240V, 50/60 Hz, 350W
- 110V version is available via a transformer ( 110AC- 220CAC)
|
Power | - Maximum: 450W
- Motor Power: 400 W
|
Mixing
| - Planetary Centrifugal Vacuum Mixing
- The centrifugal force of rotation and revolution induces convection, homogenizing the materials
- With the vacuum pressure, submicron air bubbles can be efficiently eliminated from the materials
- Max, Gravity acceleration: 438 G
- Max viscosity: 30,000 Pa S
- Speeds: Fixed speed ratio (0.6X between main plate revolution and container rotating)
- Sample Platen Rotation (revolution motion): 300 rpm - 2,000 rpm (adjustable)
- Container Spin (rotation motion): 180 rpm - 1,200 rpm (fixed at 0.6X of the revolution speed)
|
Containers
| - Six 30 ml containers made of high-density Polyethylene, are included
- Max. weight for each container+ sample is 100 g ( wet mixing ) , and 50g ( dry mixing)
- Six containers' weight must be the same.
- Customized container sizes may available upon request at an extra cost
|
Vacuum | - One 1/4 " vacuum port is located on the outside case to connect to a vacuum pump
- One156L/minute rotary vacuum pump with pipe is included
- Max. vacuum: -0.1 Mpa
|
Control Panel
| - Touch screen control panel to program speed and time
- Store up to 8 programs in memory, as shown in Fig.1
- 3 segments, as shown in Fig.2. For example:
- 800 rpm revolution speed (480 rpm rotation speed) for 60 sec;
- 1500 rpm revolution speed (900 rpm rotation speed) for 180 sec;
- 1000 rpm revolution speed (600 rpm rotation speed) for 60 sec.
- The maximum running time for each segment is 200 sec. The maximum total running time is 600 sec
|
Safety and Protection | - Safety warnings and interlocks are integrated. The unit automatically stops when
- The unit is overloaded with the sample
- The sample is loaded in an unbalanced way
- The top cover is opened
|
Compliance | - CE certified
- NRTL or CSA certification is available upon request at the extra cost
|
Warranty | - One year limited standard warranty with lifetime technical support
|
Dimension | |
Weight | |
Shipping Weight & Dimensions | |
Reference Video
|
|
Application Notes | - Always use the mixer on a level & stable surface for best performance and maximum safety
- Do not use the mixer in a hazardous atmosphere, or with flammable, explosive, corrosive, poisonous material! Check the chemical resistance of the container with different materials before loading the sample!!!
- Do not overload the mixer! Stop the mixing operation immediately if abnormal sound/vibration is observed
- Use a digital balance to make sure the sample loading is balanced before mixing
- Double-check if the containers are mounted correctly and securely before mixing
- Do not open the cover lid until the rotation has completely stopped! Do not retrieve the containers and/or put a hand close to the mixing fixture while the rotation has not completely stopped!
- Only use the included containers for the mixing operation! Double-check to make sure there is no foreign object in the mixer before mixing
- Please click underline to learn Centrifugal Force calculation
- Please do not use it under Ar gas. Please consider our MSK-PCV-310AR if Ar gas is required
|