Cell Sealing

Automatic Vacuum Sealer Integrated with Electrolyte Injection & Diffusion Stations for Pouch Battery Fabrication - MSK-113-PM

Automatic Vacuum Sealer Integrated with Electrolyte Injection & Diffusion Stations for Pouch Battery Fabrication - MSK-113-PM

기본 정보
Product Name Automatic Vacuum Sealer Integrated with Electrolyte Injection & Diffusion Stations for Pouch Battery Fabrication - MSK-113-PM
Sale Price Call for Price
Product Code MSK-113-PM
Quantity 수량증가수량감소
상품 옵션
 
MSK-113-PM is a semi-auto three-in-one vacuum sealer with a four-position rotational platform for the stream-flow processes of pouch battery fabrication including electrolyte injection, electrolyte diffusion & degassing and vacuum hot sealing. It features an air-tight chamber with a front observation window and operation gloves which allow the operation under moisture and oxygen free environment. In this technique, the pouch cell is loaded in station#1 following the electrolyte injection in station#2. Then, the cell will be transferred to station#3 for vacuum degassing & diffusion which helps with electrolyte wetting over the electrode materials. Finally, the cell will be transferred to station#4 for gas removal and hot seal under vacuum condition. This is an ideal system for pilot scale pouch battery manufacturing with accurate and efficient workflow.
Note:  This machine must be operated in dry room.


SPECIFICATIONS:


Advanced Features

  •      •  Four-position rotational platform enables the continues flow-stream process of battery cell loading,
            electrolyte injection, electrolyte diffusion & vacuum degassing and the final vacuum hot sealing.
            Please refer to pic.1 for platform configuration.
  •      •  Featured an air-tight chamber with a front observation window and operation gloves. The unit
            provides inlet and outlet valves for continues inert dry gas purging. It protects the cells from
            moisture or oxygen exposure during the process.
    Please refer to pic.2 for details.
  •      •  Two air-tight ante-chambers with pneumatic isolation gates are featured on the left (for cell load-in)
             and the right (for cell unload) sides of the chamber.
    Please refer to pic.2 for details.
  •      •  Three entrance doors with positive latches (left, right & back) provide the easy access to the
             working station adjustment and maintenance.
    Please refer to pic.3 for details.
  •      •  Large LCD touch screen on the front enable easy control over electrolyte injection amount & rate,
             vacuum diffusion/degassing period & cycles, sealing temperature & time.
    Please refer to pic.4 for
             details.
     
  •      •  The system is designed to use in a dry room

                              
               Pic.1                           Pic.2                          Pic.3             Pic.4


Input Power


  •      •  Three phases AC 380 V 50 Hz
  •      •  6KW power
  •      •  Three phases AC 220V version is available upon request


Working Gas

  •      •  0.5~0.8 Mpa high purity compressive inert gas (Ar is preferred) is required for driving the
            pneumatic system
  •      •  < -60℃ dew point
  •      •  Continues dry inert gas purging for the working chamber is required to maintain a dry
            atmosphere for electrolyte injection and diffusion



Pouch Size Adaptability

  •      •  Max. L180*W150mm
  •      •  Min. L62*W46mm*H6mm
  •      •  Large size is available upon request


Electrolyte Dispenser

  •      • 
    Electrolyte plunger metering pump is included for precise electrolyte filling (0.3% accuracy)
  •      •  Filling volume and injection rate adjustable via touch screen control


Vacuum Degassing

  •      • 
    Vacuum range:  -95 ~ 0 kPa adjustable
  •      •  Dwell Time: 0~99 seconds adjustable


Sealing Die

  •      • 
    Sealing width: 4 mm (customizable)
  •      •  Sealing length: ≤ 180 mm


Seal Pressure

  •      •  Pressue range: 0.3~0.6 Mpa adjustable.
  •      •  Consumption: ~ 0.1 L compressed air per sealing
  •      •  Attention: If a gas cylinder is used instead of air compressor(pic2), a two-stage pressure
             regulator(pic1) must be installed on the gas cylinder to limit the pressure within the
             required working range for safe operation.
    Click here to learn the installation of a gas regulator.
                pic1                pic2


Sealing Temperature

  •      • 
    Two digital temperature controllers on the front panel provide independent control for the left and
             right heating dies.
  •      •  Temperature range: 50 ~ 250 ℃ adjustable (accuracy +/- 3 ℃)
  •      •  Recommended sealing temperature: 180~190 

Sealing Time
  •      •  0 ~ 99 seconds adjustable (3 ~ 4 seconds is recommended)

Vacuum Pumps (not included)

  •      • 
    Two rotary vacuum pumps are needed for vacuum diffusion and degassing and vacuum sealing.
             Please click the picture below to purchase separately.

  •          

Machine Dimensions
   
  •      •  Footprint: W1250*D1050*H2250mm
Net Weight
  •      •  1.5 ton
Warranty
  •      •  One Year limited warranty with lifetime support
Compliance
  •      •  NRTL Certification is available upon request at extra cost

Operation Manual & Video



 



Application Notes

  •      •  Please clean the sealing dies after each use. Clean the sealing die after it has cooled down to
            avoid corrosion by the electrolyte.
  •      •  Check the level and smoothness of sealing die surface regularly. If there is a damage to the sealing
            die, please contact MTI to order a replacement.
  •      •  The featured air-tight chamber enables the operation under Ar atmosphere where Lithium Sulfur,
            Lithium Air, Lithium Solid State or Li-ion half cell will be assembled. Please click the images below
             to understand these technologies and how it fits in a glove box.