This is a compact vacuum liquid electrolyte injection system for pouch and cylindrical cell batteries.
  • MSK-113-PVM: Vacuum electrolyte injection system for pouch cell only
  • MSK113CVM: Vacuum electrolyte injection system for cylindrical cell only
  • MSK-113-CP: Vacuum electrolyte injection system for both pouch and cylindrical cell.
The device can be used inside the Ar gas glovebox.
.
SPECIFICATIONS:
Advanced Features


  • Vacuum liquid electrolyte injection for both pouch and cylinder cell batteries with the programable setting via the touchscreen controller.
  • Pouch cell vacuum sealing, electrolyte injection, vacuum standing three-in-one design
  • Cylinder cell vacuum electrolyte injection, vacuum standing, electrodes immerging under pressure
  • It could be used either in or outside of the glove box
  • Electrolyte injection speed adjustable
  • The electrolyte filler with a speed control console and injection pump for the high-precision dispensing is integrated into the system
  • Electrolyte injection could be done under different vacuum levels in order to achieve a better electrode immersion
  • Compact & desktop; One unit with PLC control
Input Power
  • Either AC110 V or AC 208 - 240 V, 50/60 Hz Single phase [Customer can choose the voltage before purchase]
  • Power: 1.2 KW
Working Gas

     pic1                    pic2
  • 0.5~0.8 Mpa high purity compressive inert gas (Ar is preferred) is required for driving the pneumatic system in the glove box
  • Continues dry inert gas purging for the working chamber is required to maintain a dry atmosphere for electrolyte injection and diffusion 
  • Air compressors and fitting are required if used in the dry room, but not included. please click here to order 
  • Attention: If a gas cylinder is used instead of an air compressor(pic2), a two-stage pressure regulator(pic1) must be installed on the gas cylinder to limit the pressure within the required working range for safe operation. Click here to learn the installation of a gas regulator
Electrolyte Dispenser
  • An electrolyte plunger metering pump is included for precise electrolyte filling; Injection Accuracy: 1%
  • During the electrolyte injection and vacuum standing under the vacuum, The liquid electrolytes would be vaporized. Please consider refilling the electrolyte if necessary
  • Electrolyte filling volume and injection rate adjustable via touch screen PLC control
Pouch & Cylinder Cell Size Adaptability
  • Pouch cells: Max. L 180 mm * W 180 mm * H 12 mm
  • Cylinder cells: 4680 (18650 and 21700 are achievable with an adapter at extra cost.)
Control Panel  Color touch screen panel to set program for vacuum level,  inert gas filling, electrolyte injection amount,  sealing temperature, and time.
  • Vacuum Degassing:
    • Vacuum range:  -95 ~ 0 kPa adjustable
    • Dwell Time: 0~99 seconds adjustable
  • Inert gas filling:  
    • Max. pressure:  110 Kpa max. adjustable
    • Dwell Time: 0~99 seconds adjustable
  • Sealing Temperature and time:
    • Two digital temperature controllers on the front panel provide independent control for the left and right heating dies.
    • Temperature range: 50 ~ 250 ℃ adjustable (accuracy +/- 2 ℃)
    • Recommended sealing temperature: 180~190
    • Sealing time:  0 ~ 99 seconds adjustable (5 ~ 6 seconds is recommended)
  • Electrolyte injection: 
    • 0.3 ml - 100 ml  programmable under normal atmosphere
    • Injecting under vacuum or inert gas selectable
Pouch Cell Sealing Die
  • Sealing width: 6 mm (Customizable)
  • Sealing length: ≤ 180 mm
Pouch Cell Sealing Pressure
  • Maximum sealing pressure: 70 kg*f
Cylindrical Cell under pressure
  • Maximum applied pressure 120 KPa
Vacuum Pump (not included)

  • Double-stage rotary vacuum pumps are needed for vacuum diffusion and degassing and vacuum sealing. Please click the picture below to purchase separately.
Dimensions                            
       For Pouch cell only              For both    Pouch + Cylindrical cell
Net Weight
  • ~65 kg
Warranty
  • One-year limited warranty with lifetime support
Compliance
  • NRTL Certification is available upon request at an extra cost
  •  the patent 201822101349.0 for the Pouch Cell Sealing Machine integrated with Electrolyte Injection MSK-113 since December 2019
Operational manual & Video
  •    
  •    
Application Notes
  • Please clean the sealing dies after each use. Clean the sealing die after it has cooled down to avoid corrosion by the electrolyte.
  • The featured air-tight chamber enables the operation under the Ar atmosphere where Lithium-Sulfur, Lithium Air, Lithium Solid-State, will be assembled. Please click the images below to understand these technologies and how it fits in a glove box.
  • Please add the high-precision digital balance to the chamber in order to monitor and evaluate the liquid electrolyte lost during the vacuum electrolyte injection. Because there might be some liquid electrolyte evaporation caused by the pressure difference between the liquid electrolyte tank and vacuum chamber.