Features and principle
Dew Point vs % | - Modular design for easy installation without professionals
- Made of stainless steel plate with 3 mm thickness
- Uniformly remove moisture without "dead corner " and "channel effect"
- Dew Point: -40ºC ( ~ 79 ppm) under the condition that has no de-gas or de-vapor equipment inside and measures in the center of the dry room with one operator.
- Power saving with quiet operation
- Only allow one person to operate inside the dry room
-
- Side view Top view Back view Layout 1 Layout 2
|
Dry Room Dimension
| - Internal Area: ~ 9 square meters ( 96.8 square feet )
- Operation Area: 2,920 mm L x 2,920 mm W x 2,100 mm H (Including buffering room 780 mm L x 650 mm W x 2,100 mm H)
- Dry room size: 3,000 mm L x 3,000 mm W x 2,400 mm H
- Dehumidification system size: 2,000 mm L x 1,000 mm W x 1,800 mm H
- Lighting and power cords are built inside the dry room
- You need 17' x 20 " ( 5 x 6 meter) space at least in an air-conditional room with PVC or rubber floor carpet to place all devices above
- The temperature inside the dry room: It is dependent on the outside temperature. The temperature may reach 20oC if the outside temperature is 25oC
|
Power requirement | - AC 220 V +/- 10%, 50 / 60Hz, Three phases
- Installed Power: 23 KW Max. (Dehumidifier: 10 kW, Water Chiller: 4.5 kW, Reserved for Dry Room: 8 kW). In fact, the operation power for the dehumidifier and water chiller is 8 kW and 4 kW, respectively.
- 40A air-breaker for power panel of dehumidifier and water chiiller {I = P/ (1.73 * U * 0.85)}.
- We highly recommend two separate circuit breakers for the dehumidifier (25A) and water chiller (15A) on the wall power source.
|
Water Cooling Requirement | - <= 7 Celcius degree cooling water
- Cooling capacity: >12 KW
- Water flow: : > 3 m³/h
- Waterport for inlet and outlet: 25 mm ( DN25 ) ( PVC tube: 25 mm ID x 32 mm OD)
- We may supply the recirculating water chiller for you at an extra cost if there is no cooling water system in your lab.
- Water Cooling System size: 1,350 mm L x 600 mm W x 1,250 mm H
-
|
Shower | - Preinstalled in the front of the door
- Single person walk-in
- 10 - 99 second cleaning time adjustable
|
Control System | - Purification limitation: Water concentration -40ºC Dew Point with the empty room
|
Air Flow | - 1,000 CMH (cubic meter per hour)
- 588 CFM (cubic feet per minute)
|
Air Turn Over | |
Dimension | - Click the picture to see the details
|
Net Weight | - 1,100 kg Including the Dehumidification system
|
Operation Demo Video |
|
Warranty | - One-year limited warranty on lifetime support
|
Application Note | - Dryroom + Glovebox combination scheme is also avilbale upon requets to process air-sensitive materials:
|
Note and Warning
| - Must wear Clean room cloth to enter the dry room as picture left for quick recovery of dew point
- Please keep the cloth in the dry room inside to keep dry ( baffle room )
- Please allow 20 - 30 minutes recovering the dew point to -40 oC when one person enters the dry room
|