OTF-1600X-III- is a split-able three-zone tube furnace with Kanthal 1650°C grade SiC heating element,  82mm OD Alumina tube and vacuum-sealed  flange. Three 30 segments temperature controllers are installed with S type thermal couples. Microprocessor-based self-tuning PID provides excellent control with no overshooting and  +/- 1°C accuracy.   It is an excellent furnace for exchanging processing tube for multi-purpose up to 1600°C.



SPECIFICATIONS:

Power Input9.0 K W
Working Voltage AC220V Single phase 50/60Hz ( 60 A breaker required)
Max. Working Temperature1600°C  ≤1 hours
Continuously Working Temperature1500°C
Recommend Heating rate5°C/min.

Processing Tube


 Alumina Tube
Size: 82 O.D x 73 I.D x 1000mm L

 click picture to order spare      click here to choose a crucible


Heat Zone Length

  •      •  Three heating zones:  200 mm / each  ( included 20 mm spacing )
  •      •  Total zone length :  600 mm  
  •      •  Constant Temperature Zone length:   350mm  ( if set 3 zone at same temperature ) +/- 2ºC.
  •      •  Accept processing tube up to 100 mm diameter


Temp. Profile at 1450ºC

     (click to enlarge)

Overall Dimensions860 mmL × 380 mmW × 680 mmH

Temperature Controller



Temperature controller interface


Optional PC control module



Optional Eurotherm 3204

Standard temperature controller:
  •      •  Proportional–integral–derivative control (PID control) and auto-tune function
  •      •  30 segments programmed with ramping, cooling and dwelling steps
  •      •  Built-in over-temperature alarm and thermocouple failure alarm
  •      •  Three S type thermcouples.
  •      •  +/- 1 ºC temperature control accuracy
  •      •  Default DB9 PC communication port (PC control module and software are sold separately.
            See
    optional.

Optional:  
  •      •  MTS-02 PC control module (also including cable and software) is an add-on option for PC
              control.
    •          º  It is recommended to purchase the module together with the furnace.
                   We install and test it before shipping.
    •          º  It is recommended to purchase the laptop (with software pre-installed) from us to
                   avoid software confliction.
    •          º  Please note the module is not sold solely in the future.
  •      •  Eurotherm 3204 Temperature Controller is optional. This package includes the communication
              cable (RS485 - USB) and software CD. Click here to view the full spec.


    European Temperature Controllers (optional upgrade)


    •      •  1 heating channel
    •      •  1 programs of 8 or 24 segment
    •      •  Alarm Relay: Form 'A' and Form ‘C’ built-in
    •      •  Digital Communications: RS485
    •      •  Temperature Accuracy:  ±  0.1ºC
    •      •  Recipes: Using a PC tool recipes can be created that can be used to change the operating
               parameters of the 3000 simply by selecting a new recipe via the HMI. This is very useful
               where multiple products are processed using the same controller but require different
               parameters to be set.



    Laptop, software & WiFi Control(Optional)

    •      •  Brand new laptop with Microsoft Window 10 and Microsoft Office 2013 (30 days free trial) for
               immediate use.
    •      •  Labview Based Temperature Control System (EQ-MTS01) enables user to edit temperature
              profile, manage heat-treatment recipe, record and plot data for MTI furnaces.
    •      •  A wireless remote control provides up to 300 meters operating range.
    •      •  Above features are available upon request at an extra cost (up to $1,000). Please contact us for
              more information.
    •      •  Note:
             The software is only compatible with MTI’s Yudian Temperature Controller

                  


    Thermal Block Placement

    •      •  Two thermal blacks are included . Please picture below tolearn how to place them inside tube
    •      •  You may order flange support to avoid tube rotating ( click Pic below right )

                        


    Vacuum Level

    •      •  10E-2 torr by quality mechanical vacuum pump
    •      •  10-5 torr by molecular pump


    Heating Elements & Thermal couples

    •      •  24 pcs  Kanthal 1650ºC grade Silicon carbide rod 
             ( 12 Dia. x 150 heating  x  374 lengths,(mm) )
    •      •  3 pcs S type thermal couple built in
    •      •  Please click picture below  to order spare heating element
    •      •  Notice: Customer will install SiC rod on site by themselves as instruction manual due to
              they are easy to damage during shipping.


    •                  


    Power Cable & Plug

    •      •  10 feet length 10-3 AWG heavy duty UL approved power cable is included. Extra length
              cable can be ordered by click picture below-left
    •      •  The plug is not included. Browse our catalog for compatible plugs or obtain one from a local
               hardware store.


                     

    Net Weight160 Kg
    Operation Instructions

    Warnings



    •      •  The tube furnaces with alumina tube are designed for using under vacuum and low pressure
               < 0.02 Mpa / 0.2 Bar/ 3 PSI
    •      •  Never use graphite crucible in alumina tube.
    •      •  Attention: A two-stage pressure regulator must be installed on the gas cylinder to limit
              the pressure to below 3 PSI for safe operation.
       
            Click here to learn the installation of a gas regulator.
    •      •  The flow rate for gases should be limited to < 200 SCCM ( or 200ml/min )
    •      •  Vacuum limit definition for all alumina tube furnaces: * Vacuum pressures may only be safely
              used up to 1500°C


    Warranty

    •      •  One year limited warranty with lifetime support (consumable parts such as processing tubes,
               and O-rings are not covered by the warranty, please order replacements at related
                products below.).  
    •      •  ATTENTION: Any damages caused by the use of corrosive and acidic gases are not
              under the coverage of MTI One Year Limited Warranty.



    Compliance

    •      •  CE Certified
    •      •  All electric components ( >24V) are UL / MET / CSA certified
    •      •  The furnace is ready to  pass TUV(UL61010) or CSA certification at extra cost.
             ( please click marks below to learn details )